This study was developed to estimate wind turbine low frequency and infrasound levels at 1238 dwellings in Health Canada's Community Noise and Health Study. In field measurements, spectral peaks were identifiable for distances up to 10 km away from wind turbines at frequencies from 0.5 to 70 Hz. These measurements, combined with onsite meteorology, were in agreement with calculations using Parabolic Equation (PE) and Fast Field Program (FFP). Since onsite meteorology was not available for the Health Canada study, PE and FFP calculations used Harmonoise weather classes and field measurements of wind turbine infrasound to estimate yearly averaged sound pressure levels. For comparison, infrasound propagation was also estimated using ISO 9613-2 (1996) calculations for 63 Hz. In the Health Canada study, to a distance of 4.5 km, long term average FFP calculations were highly correlated with the ISO based calculations. This suggests that ISO 9613-2 (1996) could be an effective screening method. Both measurements...