Beam Test Proposal of an ODR Beam Size Monitor at SLAC FFTB

2005 
ODR(Optical Diffraction Radiation) transverse beam size measurement at the SLAC FFTB at 28.5 GeV is a challenge and it requires special target and optics system, which is much difficult than the conventional ODR beam size measurement. We propose to use a curved disphased conductive slit target to recover the sensitivity in the measurement of the single bunch transverse beam size by using ODR photons from a conductive slit. In order to cancel the effect of the beam divergence, the conductive slit target surface must be curved. Also, we can obtain the focused interference pattern of the ODR photons at the detector at the shorter distance from the target than the γ 2 λ, by using lens optics system.