Single implant overdenture reinforced with a metallic framework: A 2-year clinical follow-up.
2021
Introduction To prevent single-implant overdenture (SIO) fracture, the inclusion of a framework in the overdenture has been suggested. However, no investigations verified their benefits. Objective To evaluate prosthetic maintenance events, patient satisfaction, and mastication of SIO reinforced by metallic framework users. Material and methods Fifteen volunteers had a new set of complete dentures converted into an SIO containing a framework. Maintenance events were recorded, while patient satisfaction was assessed using a visual analog scale. Masticatory performance (MP) was evaluated using the sieving method, maximum bite force (MBF) by pressure sensors, and masseter thickness by ultrasound. Measurements were performed 2, 12, and 24 months after SIO use. Repeated-measures ANOVA and paired Student's t-tests (p Results Matrix exchange was the most prevalent maintenance event (83.6%), and no SIO was fractured during the entire follow-up. Satisfaction with the SIO stability decreased (p 0.05). Conversely, MBF and masseter thickness improved after 12 and 24 months of SIO use (p Conclusions Reinforced SIO did not fracture during 2 years but requires maintenance. It improves bite force and muscle thickness, maintaining MP values. Satisfaction with SIO stability decreased in the first year of use.