Face and construct validity assessment of training models for intestinal anastomosis in low-birth-weight infants.
2021
PURPOSE It is difficult to perform intestinal anastomosis in low-birth-weight infants because the intestinal diameter is small and the discrepancy in diameter of the proximal and distal intestines is often large, but there has been no optimal-sized training model. Therefore, we developed a new intestinal anastomosis training model that imitated the size of the intestine in low-birth-weight infants, and evaluated its face and construct validity. METHODS Two intestinal models were developed with crossMedical, Inc. using a hydrophilic acrylic material (wet model) or a polyurethane soft resin (dry model). The inner diameter of the simulated intestinal tract was 15 mm on the oral end and 6 mm on the anal end. Thirteen pediatric surgeons performed anastomosis and responded to the questionnaire. RESULTS In the questionnaire, the wet model had significantly higher scores than the dry model in "appearance", "softness" and "usefulness for training". In the anastomotic results of the wet model, the anastomosis leak pressure was significantly correlated with the number of intestinal anastomotic experiences in low-birth-weight infants (correlation coefficient = 0.64, P = 0.035). CONCLUSIONS The wet-type intestinal anastomosis model showed good face validity. Its leak pressure had a significant correlation with clinical experience; thus, construct validity was demonstrated.