An endurance test of a 900 series 30-cm engineering model ion thruster

1976 
The 10,000 hour endurance test of the first engineering model 30-cm thruster (S/N 701) identified discharge chamber erosion as a life limiting problem. Modifications to minimize this problem have been implemented in the 900 series thrusters. This paper describes a test conducted to evaluate the success of these modifications. The post-test analysis results of thruster 701 are summarized and the erosion reducing modifications described. Test results for thruster 901 up to 4165 hours, when the test was interrupted by a shorted wire, are described. The conclusions of a post-test examination of thruster 901 are included. Also being evaluated was a thermal vacuum breadboard SCR series inverter power processor which is described.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    14
    Citations
    NaN
    KQI
    []