Low frequency noise of mid-wavelength interband cascade photodetectors up to 300 K

2019 
This article presents the InAs/GaSb type-II superlattice interband cascade photodetector low-frequency noise analysis. Presented noise measurements were conducted in temperature range 77-300 K and in frequency range 1-10 kHz. The spectral characteristics of the detector noise at various voltages are analyzed. The measured power spectral density is compared to the theoretical prediction. This comparison suggests that noise estimates based on the dark current may not always be valid and the noise source is difficult to be extract. We showed two samples, one of which was characterized by a large leakage currents contribution being directly translated into increased noise.