A P300-Based BCI System Using Stereoelectroencephalography and Its Application in A Brain Mechanistic Study

2020 
Stereoelectroencephalography (SEEG) signals can be obtained by implanting deep intracranial electrodes. SEEG depth electrodes can record brain activity from the shallow cortical layer and deep brain structures, which is not achievable through other recording techniques. Moreover, SEEG has the advantage of a high signal-to-noise ratio (SNR). Therefore, it provides a potential way to establish a highly efficient brain-computer interface (BCI) and aid in understanding human brain activity. In this study, we implemented a P300-based BCI using SEEG signals. A single-character oddball paradigm was applied to elicit P300. To predict target characters, we fed the feature vectors extracted from the signals collected by five SEEG contacts into a Bayesian linear discriminant analysis (BLDA) classifier. Thirteen epileptic patients implanted with SEEG electrodes participated in the experiment and achieved an average online spelling accuracy of 93.85%. Moreover, through single-contact decoding analysis and simulated online analysis, we found that the SEEG-based BCI system achieved a high performance even when using a single signal channel. Furthermore, contacts with high decoding accuracies were mainly distributed in the visual ventral pathway, especially the fusiform gyrus (FG) and lingual gyrus (LG), which played an important role in building P300-based SEEG BCIs. These results might provide new insights into P300 mechanistic studies and the corresponding BCIs.