The ITER TF Coils will consist of two main components; the WP which is formed by the assembly of seven double pancakes, superconducting windings inserted into stainless steel radial plates and the stainless steel structural casing which forms the mechanical interface between TF coils and the remainder of the ITER machine. The final step in assembly of the TF Coils will be the insertion of the WP into the structural casing. The insertion procedure must achieve two critical objectives; accurate geometric location, 1 mm, of the WP current center line with respect to the casing reference faces and the full mechanical location of the WP within the casing to facilitate the uniform transfer of the electromagnetic forces to the casing and the ITER TF keystone structure.