Realization of a high quality factor resonator with hollow dielectric cylinders for axion searches

2020 
Abstract The realization and characterization of a high quality factor resonator composed of two hollow-dielectric cylinders with its pseudo-TM030 mode resonating at 10.9GHz frequency is discussed. The quality factor was measured at the temperatures 300K and 4K obtaining  Q 300 K = ( 150 , 000 ± 2 , 000 ) and  Q 4 K = ( 720 , 000 ± 10 , 000 ) respectively, the latter corresponding to a gain of one order of magnitude with respect to a traditional copper cylindrical-cavity with the corresponding TM010 mode resonating at the same frequency. The implications to dark-matter axion-searches with cavity experiments are discussed showing that the gain in quality factor is not spoiled by a reduced geometrical coupling  C 030 of the cavity mode to the axion field. This reduction effect is estimated to be at most 20%. Numerical simulations show that frequency tuning of several hundreds MHz is feasible.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    26
    References
    0
    Citations
    NaN
    KQI
    []