Using central composite experimental design to optimize the degradation of real dye wastewater by Fenton and photo-Fenton reactions
2014
Abstract This work focuses on the use of Fenton reagent and UV-irradiation, in a lab-scale experiment, for the treatment of real dye wastewater coming from a Spanish textile manufacturer. Response surface methodology and a 2 3 factorial design were used to evaluate the effects of the three independent variables considered for the optimization of the oxidative process: temperature, Fe (II) and H 2 O 2 concentrations, for a textile wastewater generated during a dyeing process with chemical oxygen demand of 1705 mg L −1 O 2 at pH = 3. Wastewater degradation was followed in terms of chemical oxygen demand reduction. In the optimization, the correlation coefficients for the model ( R 2 ) were 0.985 and 0.990 for Fenton and photo-Fenton treatments respectively. Optimum reaction conditions at pH = 3 and temperature = 298 K were [H 2 O 2 ] = 73.5 mM and [Fe(II)] = 1.79 mM. The combination of Fenton, Fenton-like and photon-Fenton reactions has been proved to be highly effective for the treatment of such a type of wastewaters, and several advantages for this technique arise from the study. Under optimum conditions, 120 min of treatment resulted in a 62.9% and 76.3% reduction in chemical oxygen demand after Fenton and photo-Fenton treatments respectively.