Liquefied Noble Gas Detectors for Detection of Nuclear Materials

2013 
Liquefied noble gas (LNG) detectors have already been successfully employed in areas of fundamental particle physics research due to features such as their high energy resolution, fast response times, excellent discrimination between neutron and gamma-ray interactions, and relatively low cost. Such detectors are also attractive for nonintrusive inspection for the presence of special nuclear material (SNM) in large-scale objects such as cargo containers and trucks. An effective method of interrogation involves pulsing the object being interrogated with neutrons, which induces fission in the SNM. The fission reaction promptly releases gamma rays and neutrons. This reaction can be distinguished from background through the coincidence measurement of these particles striking multiple detectors. Rapiscan Laboratories, Yale University Physics Department, and Adelphi Technology have constructed two 18-L liquid argon prototype detectors to investigate the suitability of LNG detectors in performing this form of interrogation. The pulse shape, energy resolution, time resolution, detector efficiency, and the effects of doping with xenon were measured.