Patellar Fractures: An Innovative Surgical Technique With Transosseous Suture to Avoid Implant Removal.

2015 
Purpose. To describe a new surgical procedure and its outcomes: osteosynthesis with high-resistance sutures, avoiding metallic implants. Open sky osteosynthesis with Kirschner and cerclage wiring is the current gold standard for patella fractures. Favorable functional outcomes have been observed, although implant removal is required in many cases due to the prominent wires under the skin. New implants have been sought after to minimize the need for second surgeries. Methods. Eight patients, aged between 25 and 61 years, with a minimum follow-up of 24 months, were included in the present study. The surgical procedure consists of open reduction followed by internal fixation performing 3 longitudinal tunnels crossing double high-resistance sutures within these tunnels and suturing among them. Next, an anterior cerclage with parenchymal suture was performed. Results. During follow-up, no secondary fracture displacement was observed. No patient required or requested implant removal. Functional outcomes were eq...