An MMI-based wavelength combiner employing non-uniform refractive index distribution

2014 
A novel wavelength combiner using non-uniform refractive index distribution within a multimode interference device is proposed and simulated. The refractive index step creates separate localized modes with different effective refractive indices and two modes are strongly excited which form the basis of an interferometer. We applied the concept to 1.30/1.31 μm and 1.31/1.55 μm wavelength combiners on an InP substrate. The lengths of the devices are 1272 μm and 484 μm with simulated insertion losses of 0.6 dB and 0.67 dB respectively.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    12
    References
    5
    Citations
    NaN
    KQI
    []