Geometric Accuracy of Frameless Based Image Guided Stereotactic Radiosurgery of Trigeminal Neuralgia using Brainlab's Exactrac 6-D Robotic System

2009 
Materials/Methods: A BrainLab frameless mask was made for a Lucite phantom with an EDR film sandwiched between the two parts of the phantom with a target defined by a 1.5 mm diameter spherical BB marker taped on the film. A CT scan of the phantom was performedusing 1.25mmslice thickness,and512 x512matrix,andthe headandnecklocalizer.Themarkerwasdefinedas the target in the BrainScan software. The same protocol used in our institution for the treatment of trigeminal neuralgia was used (7 non-coplanar circular arcs with a 4mm cone) to plan and treat the marker using the stereoscopic image guidance. The phantom was imaged at each couch angle, and the images were fused with the DRRs using the autofusion option of the ExacTrac software. ExacTrac x-ray correction was applied until the phantom was within an acceptance criterion of 0.5mm, and 0.5 degree. The EDR film was developed, and scanned in high resolution using Vidar Dosimetry-Pro scanner, and RIT Technology software. The same technique was repeated for a second target. The displacement of the centroid of the optical density on the film, and the position of the marker was calculated using the RIT Technology software, and averaged for the 2 targets. Furthermore, retrospective study of 44 patients who underwent frameless image guided radiosurgery of the trigeminal neuralgia since October 2007 was performed. 514 stereoscopic images (Ave. 12 images/patient), and their shifts were reviewed, and reported. Results:Geometricaccuracyof 0.48±0.55 mmwasachievedon2different targetswiththe 4mmcone.Thegeometric accuracyof the target depends significantly on the landmarks used for autofusion of the images. The average 3-D movement of the isocenter in the 44 patients post imaging, and autofusion of the DRR, and the stereoscopic images was 0.49 ± 0.44 mm. Conclusions: Accuracy of target localization achieved with the BrainLab frameless technique approaches that attainable with invasive stereotactic frames. However, since the ExacTrac autofusion software heavily relies on the bony landmarks, special care must be made with the frameless system by taking at least one image per bed position to ensure accurate treatment of the trigeminal nerve. Author Disclosure: J. Rahimian, None; M.R. Girvigian, None; J.C.T. Chen, None; R. Rahimian, None; M.J. Miller, None.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    1
    References
    4
    Citations
    NaN
    KQI
    []