Revised manuscript prepared for submission to appl. Radiat. Isot. (July 7, 2020) ICNCT-18 special issue (presentation code: Pa Ph5 04) comparison of different methods for the shielding analysis of an AB-BNCT facility based on the Be(p,xn) reaction with 30-MeV protons
2020
Abstract Five shielding calculation methods were employed to estimate the dose rate distribution around an accelerator-based boron neutron capture therapy facility. Their performances were compared in terms of accuracy and efficiency. The results indicate that the hybrid deterministic/Monte Carlo method is the most efficient in the context of accurate modeling and simulation, whereas the analytical approximation with pre-generated source terms and attenuation lengths is preferable in the design phase because of its simplicity and ease of verification while retaining a reasonable accuracy.