A Buck Power Factor Correction Converter with Predictive Quadratic Sinusoidal Current Modulation and Line Voltage Reconstruction

2016 
A buck power factor correction (PFC) converter operating in continuous conduction mode (CCM) is influenced by the dead zone, which introduces distortion related to the input line voltage. Such phenomenon limits the maximum power factor (PF) and the minimum total harmonic distortion (THD) achievable. By deriving a methodology to achieve predictive line voltage reconstruction (PLVR), the influence of the dead zone is mitigated. With the prediction of quadratic sinusoidal current modulation ( ${\text{PS}}^2{\text{CM}}$ ), the line current is shaped into sinusoid waveform that is in-phase with input line voltage, crucial for. Consequently, the proposed CCM buck PFC can achieve high PF, low THD, and efficiency simultaneously. A test chip was fabricated in $0.5\hbox{-}\upmu {\text{m}}$ Bipolar-CMOS-DMOS (BCD) process. The experimental results show a peak PF of 0.95 and a peak efficiency of 98% at 110 ${\text{V}}_{\text{ac}}$ .
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    18
    References
    13
    Citations
    NaN
    KQI
    []