Comparison of endotoxin levels and Gram-negative bacteria under different conditions in microbial laboratories and a biowaste site

2011 
Abstract In this study, we assessed airborne endotoxin levels in university laboratories, hospital diagnostic laboratories, and a biowaste site. We also investigated indoor and outdoor sampling, sampling site, type of ventilation system, presence of open biowaste boxes, weather, and detection of Gram-negative bacteria (GNB). A total of 69 air samples were collected from 11 facilities in three institutions. Average total airborne endotoxin levels ranged from −3 , with an overall mean of 1.03 EU m −3 . Endotoxin levels were high in window-ventilated facilities, in facilities in which GNB were detected; levels were also high when it was rainy (all p s  r  = 0.70, p