Echogenic Technology Improves Cannula Visibility during Ultrasound-Guided Internal Jugular Vein Catheterization via a Transverse Approach
2012
Objective. Echogenic technology has recently enhanced the ability of cannulas to be visualized during ultrasound-guided vascular access. We studied whether the use of an EC could improve visualization if compared with a nonechogenic vascular cannula (NEC) during real-time ultrasound-guided internal jugular vein (IJV) cannulation in the intensive care unit (ICU).
Material and Methods. We prospectively enrolled 80 mechanically ventilated patients who required central venous access in a randomized study that was conducted in two medical-surgical ICUs. Forty patients underwent EC and 40 patients were randomized to NEC. The procedure was ultrasound-guided IJV cannulation via a transverse approach. Results. The EC group exhibited increased visibility as compared to the NEC group (88% ± 8% versus 20% ± 15%, resp. ). There was strong agreement between the procedure operators and independent observers (; 95% confidence intervals assessed by bootstrap analysis = 0.87–0.95; ). Access time (5.2 s ± 2.5 versus 10.6 s ± 5.7) and mechanical complications were both decreased in the EC group compared to the NEC group (). Conclusion. Echogenic technology significantly improved cannula visibility and decreased access time and mechanical complications during real-time ultrasound-guided IJV cannulation via a transverse approach.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
25
References
5
Citations
NaN
KQI