Analysis of the Gray-Value Reproducibility and Noise of a Direct Digital Radiography System

2019 
A radiografia digital representa um grande avanco na radiologia bucomaxilofacial porque incorpora a tecnologia informatica na captura, interpretacao e arquivamento de imagens radiograficas. Estudos anteriores demonstraram que e possivel usar os valores de cinza no diagnostico e na proservacao das lesoes osseas. No entanto, essas aplicacoes dependem da qualidade do sistema radiologico e do tempo de exposicao. O objetivo deste estudo foi avaliar a reprodutibilidade do valor de cinza e o ruido produzido pelo sistema IDA da Dabi Atlante, um sistema de radiografia digital direto. As radiografias foram obtidas de maneira padronizada (70 kV, 7 mA e filtracao de 2,2 mm) com um sensor digital direto e um penetrometro colocados em um fantoma a uma distância de filme-foco de 30 cm. Dez imagens radiograficas consecutivas foram obtidas com tempos de exposicao de 0,10-s, 0,15-s e 0,20-s. Os valores de cinza foram analisados em cinco regioes de interesse (ROIs): tecido osseo (TO), tecido mole (TM) e tres degraus do penetrometro (Degrau 1, Degrau 2 e Degrau 3). Os valores de cinza medios diferiram significativamente entre os tempos de exposicao (p <0,05) em todos as cinco ROIs. A ROI com maior variabilidade do valor de cinza (25,36%) e ruido (9,46%) foi TM. Em conclusao, a reprodutibilidade do valor de cinza e o ruido do sistema IDA variam entre areas com radiolucencia diferente. Assim, atencao especial e necessaria para o diagnostico e proservacao de lesoes radiolucentes devido a interferencia dos valores cinza relativamente alta. Palavras-chave: Radiografia Dentaria Digital. Reprodutibilidade dos Testes. Diagnostico por Imagem. Abstract The digital radiograph represents a great advance in oral maxillofacial radiology because it incorporates informatics technology in the capture, interpretation, and archiving of radiographic images. Previous studies have demonstrated that it is possible to use gray values in bone lesion diagnosis and follow-up. However, these applications depend on radiograph system quality and exposure time. The aim of this study was to evaluate the gray-value reproducibility and noise produced by Dabi Atlante’s IDA system, a direct digital radiography system. Radiographs were obtained in a standardized manner (70 kV, 7 mA, and 2.2-mm filtration) with a direct digital sensor and a stepwedge placed in a phantom at a 30-cm focus-film distance. Ten consecutive x-ray imaging series were completed at 0.10-s, 0.15-s, and 0.20-s exposure times. Gray values were analyzed in five regions of interest (ROIs): bone tissue (BT), soft tissue (ST), and three stepwedge steps (Step 1, Step 2, and Step 3). Mean gray values differed significantly across exposure times ( p < .05) in all five ROIs. The ROI with the greatest gray-value variability (25.36%) and noise (9.46%) was ST. In conclusion, gray-value reproducibility and noise of the IDA system vary across areas with differing radiolucency. Thus, special attention is necessary for the diagnosis and follow-up of radiolucent lesions due to relatively high gray-value interference. Keywords: Radiography, Dental, Digital. Reproducibility of Results. Diagnostic Imaging.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    18
    References
    0
    Citations
    NaN
    KQI
    []