Radiation temperature measurement of optical thick hypersonic combustion flow
2017
Temperature is a critical parameter to diagnose the high temperature hypersonic combustion flow. A fiber-spectrometer
based measurement system and the correlated theoretical models to measure the radiation temperature of the “optical
thick” hypersonic combustion flow were established in this paper. The spectral responsivity of the fiber-spectrometer
based measurement system was measured at NIM in lab condition, and the spectral radiance and emissivity of the
hypersonic combustion flow were measured in-situ at the combustion wind tunnel of BISLMV. Preliminary experimental
results showed the spectral emissivity of the combustion flow was about 0.1 in the spectral range 500-800nm without
strong spectral selection, which resulted in the radiation temperature about 2200 K, with relative standard uncertainty
about 10%.