Influence of preoperative mechanical bone quality and bone mineral density on aseptic loosening of total hip arthroplasty after seven years

2003 
Abstract Objective. To test mechanical bone quality and bone mineral density of the femoral head at the day of implantation as indicators for femoral prosthesis loosening. Methods. Mechanical bone quality of a femoral head slice was assessed by destructive compression testing combined with bone mineral density measurements using peripheral quantitative computed tomography. Fourteen patients with walking pains were attainable for a radiographical follow-up mean 7.1 years after implantation. Results. Radiolucent lines along the stem were evident in 11 of 14 femurs, most of them seen in Gruen zones 7, 6, 1, 3, 14, and showed strong correlations to preoperative bone strength ( r =−0.80; P r =−0.75; P =0.002), yet not to bone mineral density ( r =−0.67; P =0.009). Slight varus deviations P =0.006), and stiffness to 61% ( P =0.038), while bone mineral density did not differ significantly. Conclusions. Femoral prosthesis loosening after seven years can be predicted by mechanical bone quality of the femoral head at the time of implantation. Bone mineral density measurements may also indicate future stem loosening but have to interpreted carefully, keeping in mind a poorer predictive value. Relevance Indications and choice of type of hip arthroplasty should be balanced in osteoporotic bones in particular. While preoperative bone mineral density measurement allows the prediction of mechanical bone quality, its relevance in predicting failure in arthroplasty treatment remains unclear.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    37
    References
    20
    Citations
    NaN
    KQI
    []