Sampling and analysis of airborne methylbromide

1989 
Air sampling of methylbromide using 900 mg HBr-treated activated charcoal tubes, followed by solvent desorption and FID or ECD chromatographic analysis, makes it possible to evaluate concentrations ranging from 0.2 ppm (1 mg×m−3) to 250 ppm (1g×m−3) at ambient temperature even with a high hygrometric level. Thermal desorption does not lead to satisfactory results.