Experimental Investigation on the Load Signature Parameters for Non-Intrusive Load Monitoring

2015 
One of the most important design decisions in Non-Intrusive Load Monitoring (NILM) systems is choosing which electrical parameters will be used to define load signatures. In this paper, we present an experimental study where several electrical quantities of common home appliances were measured, in order to identify the most adequate to perform load disaggregation. It was found that active power, reactive power, rms voltage, and the first five odd harmonics of the current and voltage signals comprises the best set of parameters to define the signatures of residential loads. Streszczenie. W artykule zaprezentowano eksperymentalne studium w ktorym zmierzono parametry typowych urządzen elektrycznych w celu określenia i zestawienia obciązen. Stwierdzono ze moc czynna, moc bierna, napiecie skuteczne i pierwsze piec nieparzystych harmonicznych prądu mogą stanowic podstawe do prognozowania obciązen. Badania parametrow urządzen dla nieinwazyjnego monitorowania obciązen.