Rapid Determination of Dichlofluanid Residues in Vegetables Using Dispersive-SPE Sample Preparation Combined with Gas Chromatography-Mass Spectrometry.

2016 
A method for rapid determination of dichlofluanid residue in vegetables using dispersive solid-phase extraction (dispersive-SPE) sample preparation combined with gas chromatography-mass spectrometry (GC-MS) was developed. Samples were extracted with actone-ethyl acetate (1:1, V/V), and then detected by GC-MS with an external standard method after being purified by optimized primary secondary amine, graphitized carbon black and anhydrous magnesium sulphate (MgSO4). It turned out that dichlofluanid showed a good linearity (y= 2.7E+ 5x- 2710.5) over the range of 0.02-2.00 mg/L with a correlation coefficient of 0.9994. The limit of detection was 0.13 μg/kg (S/N = 3) and the limit of quantification was 0.43 µg/kg (S/N = 10). The recoveries of the dichlofluanid were in the range of 73.3-106.7, 83.3-116.7 and 83.3 ∼ 106.7% with the spiked levels of 0.01, 0.02 and 0.05 mg/kg, and the relative standard deviations were in the range of 4.1-22.3%. Compared with the reported literature, the method is more simple, rapid, sensitive, reliable and can be applied to many vegetables.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    18
    References
    2
    Citations
    NaN
    KQI
    []