Cardiac. Tamponade After Removal Of The Epicardial Pacing Wires And Successfully Managed With Emergency Exploratory Sternotomy (EES).
2012
Summary : We are presenting a case of removal of pacing wire post operatively in an anticoagulated lady with double valve replacement (tissue valves), who developed cardiac :ide and collapsed, and was successfully resuscitated after emergency exploratory - 1, (EES). Discussion: The incidence of pulling the pacing wire occurred 13 days after the operation in an anticoagulated patient. The insertion and removal of the pacing wires require a special protocol. Epicardial pacing wire removal(EPWR) is a procedure performed on postoperatice cardiac surgery patients.