Precision in Wedge Off-axis Using Independent Dose Verification.
2017
: It is essential for quality assurance to verify the safety of each individual patient's plan in radiation therapy. The tolerance level for independent verification of monitor unit calculations for non-IMRT clinical radiotherapy has been shown in the AAPM TG114. Thus, we investigated the precision of independent MU (dose) verification considering a wedge off-axis calculation and we conducted a study at twelve institutes for independent verification with the wedge off-axis calculation. The results obtained with the wedge off-axis calculation showed better agreement with the treatment planning system calculation results than those without the former calculation in a phantom study and in the patient retrospective study. The confidence limits with the wedge off-axis calculation were 2.2±3.4% and 2.0±4.3% for the plans with a physical wedge and a non-physical wedge in the patient study, respectively. However, the confidence limits were over 5% without the off-axis calculation. From our multi-institutional study, the results suggested that the tolerance level for the wedge off-axis plan would be 5% when considering the wedge off-axis calculation and the level was similar to that of the treatment planning system using other conventional irradiation techniques.