The present work discuses new findings in the electrochemistry of naproxen over graphite electrodes. This new approach, allows the proposal of a simple and competitive low-cost method to carry out naproxen’s voltammetric quantification. Naproxen’s indirect quantification through an adsorption anodic wave was performed at a graphite bar electrode using differential pulse voltammetry. An anodic current maximum was recorded at a potential of −0.3 V referred to a saturated Ag/AgCl reference electrode. The calibration plot having a correlation coefficient of 0.990, sensibility of 4.19±0.62 µA cm3 µg−1, with detection and quantification limits of 0.68 and 3.3 µg cm−3, respectively.