Quantifying the spatial and temporal variation of ground-level ozone in the rural Annapolis Valley, Nova Scotia, Canada using nitrite-impregnated passive samplers.

2009 
Abstract The spatiotemporal variability of ground-level ozone (GLO) in the rural Annapolis Valley, Nova Scotia was investigated between August 29, 2006, and September 28, 2007, using Ogawa nitrite-impregnated passive diffusion samplers (PS). A total of 353 PS measurements were made at 17 ambient and 1 indoor locations over 18 sampling periods ranging from 2 to 4 weeks. The calculated PS detection limit was 0.8 ±0.02 parts per billion by volume (ppbv), for a 14-day sampling period. Duplicate samplers were routinely deployed at three sites and these showed excellent agreement (R 2 values of 0.88 [n =11], 0.95 [n =17], and 0.96 [n =17]), giving an overall PS imprecision value of 5.4%. Comparisons between PS and automated continuous ozone analyzers at three sites also demonstrated excellent agreement with R 2 values of 0.82, 0.95, and 0.95, and gradients not significantly different from unity. The minimum, maximum, and mean (±1σ) ambient annual GLO concentrations observed were 7.7, 72.1, and 34.3 ± 10.1 ppbv,...