Quantification of voriconazole in human bronchoalveolar lavage fluid using high-performance liquid chromatography with fluorescence detection

2013 
Abstract The quantification of voriconazole concentration in lung epithelial lining fluid to facilitate the management of pulmonary fungal colonisation or aspergillosis is of increasing interest. An accurate and reproducible high-performance liquid chromatography method to quantify voriconazole in human bronchoalveolar lavage (BAL) fluid was developed and validated. BAL samples were concentrated by freeze-drying and reconstituted with water prior to deproteinisation. Separation was achieved with a C18 column employing fluorescence detection (excitation: 260 nm, emission: 370 nm). The calibration curves were linear from 2.5 to 500 ng/mL. The intra- and inter-day precisions were within 7%. Accuracies ranged from 102% to 107%. The clinical applicability was established by successful measurement of voriconazole concentrations in lung transplant recipients. The assay provides an alternative approach for those with negligible access to liquid chromatography–tandem mass spectrometry instrumentation.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    0
    Citations
    NaN
    KQI
    []