Boron-10 lined RPCs for sub-millimeter resolution thermal neutron detectors: Feasibility study in a thermal neutron beam

2018 
The results of an experimental feasibility study of a position sensitive thermal neutron detector based on a resistive plate chamber (RPC) are presented. The detector prototype features a thin-gap (0.35 mm) hybrid RPC with an aluminium cathode lined with a 2 ${\mu}$m thick $^{10}B{_4}C$ neutron converter layer enriched in $^{10}B$ and a float glass anode. A detection efficiency of ${\approx}$ 6.2 ${\%}$ was measured for the neutron beam (${\lambda}$ =2.5 ${\AA}$) at normal incidence. A spatial resolution better than 0.5 mm FWHM was demonstrated.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    21
    References
    0
    Citations
    NaN
    KQI
    []