The Development of a Sampling System for Determining Odor Emission Rates from Areal Surfaces: Part I. Aerodynamic Performance

1995 
Abstract An improved portable odor sampling system (OSS) of the wind tunnel type was designed to determine odor emissions from areal sources. The aerodynamics of the odor emission hood was observed using a number of smoke tests and dry ice tests. The velocity profiles were also measured horizontally and vertically in the hood by an anemometer. Modifications in the form of an extension inlet duct, flat vanes, and a baffle were necessary to achieve repeatable, uniform, and steady velocity profiles inside the hood. The optimum velocity for use of the OSS was found to be 0.33 m/s, based upon the aerodynamic performance of the OSS and the sensitivity of the anemometer at a lower velocity.