Nickel and Sulfur Speciation of Residual Oil Fly Ashes from Two Electric Utility Steam-Generating Units

2005 
Abstract Representative duplicate fly ash samples were obtained from the stacks of 400- and 385-MW utility boilers (Unit A and Unit B, respectively) using a modified U.S. Environmental Protection Agency (EPA) Method 17 sampling train assembly as they burned 0.9 and 0.3 wt % S residual (No. 6 fuel) oils, respectively, during routine power plant operations. Residual oil fly ash (ROFA) samples were analyzed for Ni concentrations and speciation using inductively coupled plasma-atomic emission spectroscopy, X-ray absorption fine structure (XAFS) spectroscopy, and X-ray diffraction (XRD). ROFA deionized H2O extraction residues were also analyzed for Ni speciation using XAFS and XRD. Total Ni concentrations in the ROFAs were similar, ranging from 1.3–1.5 wt %; however, stack gas Ni concentrations in the Unit A were 0.990 μg/Nm3 compared with 0.620 μg/Nm3 for Unit B because of the greater residual oil feed rates employed at Unit A to attain higher 400-MW load conditions with a lower heating value oil. Ni speciati...
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    15
    References
    6
    Citations
    NaN
    KQI
    []