Noncontrast-Enhanced MR-Based Conductivity Imaging for Breast Cancer Detection and Lesion Differentiation.

2021 
BACKGROUND There is increasing interest in noncontrast-enhanced MRI due to safety concerns for gadolinium contrast agents. PURPOSE To investigate the clinical feasibility of MR-based conductivity imaging for breast cancer detection and lesion differentiation. STUDY TYPE Prospective. SUBJECTS One hundred and ten women, with 112 known cancers and 17 benign lesions (biopsy-proven), scheduled for preoperative MRI. FIELD STRENGTH/SEQUENCE Non-fat-suppressed T2-weighted turbo spin-echo sequence (T2WI), dynamic contrast-enhanced MRI and diffusion-weighted imaging (DWI) at 3T. ASSESSMENT Cancer detectability on each imaging modality was qualitatively evaluated on a per-breast basis: the conductivity maps derived from T2WI were independently reviewed by three radiologists (R1-R3). T2WI, DWI, and pre-operative digital mammography were independently reviewed by three other radiologists (R4-R6). Conductivity and apparent diffusion coefficient (ADC) measurements (mean, minimum, and maximum) were performed for 112 cancers and 17 benign lesions independently by two radiologists (R1 and R2). Tumor size was measured from surgical specimens. STATISTICAL TESTS Cancer detection rates were compared using generalized estimating equations. Multivariable logistic regression analysis was performed to identify factors associated with cancer detectability. Discriminating ability of conductivity and ADC was evaluated by using the areas under the receiver operating characteristic curve (AUC). RESULTS Conductivity imaging showed lower cancer detection rates (20%-32%) compared to T2WI (62%-71%), DWI (85%-90%), and mammography (79%-88%) (all P < 0.05). Fatty breast on MRI (odds ratio = 11.8, P < 0.05) and invasive tumor size (odds ratio = 1.7, P < 0.05) were associated with cancer detectability of conductivity imaging. The maximum conductivity showed comparable ability to the mean ADC in discriminating between cancers and benign lesions (AUC = 0.67 [95% CI: 0.59, 0.75] vs. 0.84 [0.76, 0.90], P = 0.06 (R1); 0.65 [0.56, 0.73] vs. 0.82 [0.74, 0.88], P = 0.07 (R2)). DATA CONCLUSION Although conductivity imaging showed suboptimal performance in breast cancer detection, the quantitative measurement of conductivity showed the potential for lesion differentiation. EVIDENCE LEVEL 1 TECHNICAL EFFICACY: Stage 2.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    38
    References
    0
    Citations
    NaN
    KQI
    []