Compensation of BPM chamber motion in PLS orbit feedback system

2007 
The false BPM reading resulting from the BPM vacuum chamber motion due to thermal load change by synchrotron radiation is compensated by the real-time monitoring of the chamber position in the PLS orbit feedback system. The BPM chamber moves up to 20 mum during the beam refill and the chamber motion has a time constant of about one and half hour, which is related to thermal equilibrium of the vacuum chamber. To monitor the BPM chamber motion, LVDTs with 0.2 mum reading accuracy were installed on all BPM chambers, and the measured data are used in the orbit feedback every 1 minute. In this paper, we will describe how serious the BPM chamber motion are and how well it is compensated.