Ultrasonic Array Imaging Through an Anisotropic Austenitic Steel Weld Using an Efficient Ray-tracing Algorithm

2016 
Abstract Ultrasonic inspection of austenitic welds is challenging due to their highly anisotropic and heterogeneous microstructure. The weld anisotropy causes a steering of the ultrasonic beam leading to a number of adverse effects upon ultrasonic array imagery, including defect mislocation and aberration of the defect response. A semi-analytical model to simulate degraded ultrasonic images due to propagation through an anisotropic austenitic weld is developed. Ray-tracing is performed using the A ⁎ path-finding algorithm and integrated into a semi-analytical beam-simulation and imaging routine to observe the impact of weld anisotropy on ultrasonic imaging. Representative anisotropy weld-maps are supplied by the MINA model of the welding process. A number of parametric studies are considered, including the magnitude and behaviour of defect mislocation and amplitude as the position of a fusion-face defect and the anisotropy distribution of a weld is varied, respectively. Furthermore, the use of the model to efficiently simulate and evaluate ultrasonic image degradation due to anisotropic austenitic welds during an inspection development process is discussed.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    40
    References
    13
    Citations
    NaN
    KQI
    []