Radiologically guided placement of pull-type gastrostomy tubes.
1997
PURPOSE: To evaluate percutaneous placement of pull-type gastrostomy tubes that has traditionally necessitated endoscopic guidance. MATERIALS AND METHODS: From September 1995 through March 1997, 63 pull-type gastrostomy tubes were placed in 64 patients. Retrograde catheterization of the esophagus was performed through the stomach. Then the gastrostomy tube was pulled through from the mouth into the stomach. RESULTS: Gastrostomy tube placement was successful in 63 (98%) of 64 patients in 65 attempts. One procedure was stopped when the patient reported chest pain after gastric insufflation, and a second placement attempt was initially unsuccessful. Major complications occurred in three (5%) patients: exit site infection necessitating tube removal (n = 2) and prolonged bleeding necessitating transfusion (n = 1). Minor complications occurred in six (9%) patients: failure of placement (n = 2), exit site infection (n = 1), leakage around the tube (n = 1), tube migration (n = 1), and inadvertent tube removal (n ...
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
0
References
49
Citations
NaN
KQI