Validation of IFMIF liquid Li target for IFMIF/EVEDA project
2015
Abstract A liquid-Li free-surface stream flowing at 15 m/s under a high vacuum of 10 −3 Pa is to serve as a beam target for the planned International Fusion Materials Irradiation Facility (IFMIF). The Engineering Validation and Engineering Design Activities (EVEDA) for the IFMIF is implemented under the Broader Approach. As a major activity for the Li target, the EVEDA Li test loop (ELTL) was constructed by the Japan Atomic Energy Agency. The present study demonstrates a stable Li target that satisfies the IFMIF design conditions (250 °C, 15 m/s, 10 −3 Pa) and presents the procedure for operating the Li target which consists of seven stages. We used a laser-based method to verify that the Li target is adequately stable. In addition, we examine cavitation occurring during startup of the Li target, and consequently, determine the appropriate startup pressure.