Evaluation of microgap size and microbial leakage in the connection area of 4 abutments with Straumann (ITI) implant.

2012 
A microgap between implant and abutment can lead to mechanical and biological problems such as abutment screw fracture and peri-implantitis. The aim of this study was to evaluate microgap size and microbial leakage in the connection area of 4 different abutments to ITI implants. In this experimental study, 36 abutments in 4 groups (including Cast On, Castable, Solid, and Synocta abutments) connected to Straumann fixtures (with their inner part inoculated with bacterial suspension) and microbial leakage were assessed at different times. The size of the microgap in 4 randomized locations was then measured by scanning electron microscope. The data were analyzed by SPSS software and by 1-way variance statistical test, Kruskal-Wallis, and their supplementary tests (Mann-Whitney HSD and Tukey's; α = .05) at the next step. The effect of using different types of abutments was significant on the mean microgap size (P < .001) and on the mean number of leaked colonies (CFU/mL) through the connection area of the impl...