Combining urine color and void number to assess hydration in adults and children.

2021 
BACKGROUND/OBJECTIVES To test the diagnostic ability of two combined practical markers for elevated urine osmolality (underhydration) in free-living adults and children. SUBJECTS/METHODS One hundred and one healthy adults (females n = 52, 40 ± 14 y, 1.70 ± 0.95 m, 76.7 ± 17.4 kg, 26.5 ± 5.5 kg/m2) and 210 children (females = 105, 1.49 ± 0.13 m, 43.4 ± 12.6 kg, 19.2 ± 3.2 kg m-2) collected urine for 24-h. Urine was analyzed for urine osmolality (UOsm), color (UC), while the number of voids (void) was also recorded. Receiver Operating Characteristic (ROC) analysis was performed for UC, void, and combination of UC and void, to determine markers' diagnostic ability for detecting underhydration based on elevated UOsm (UOsm ≥ 800 mmol kg-1). RESULTS Linear regression analysis revealed that UC was significantly associated with UOsm in both adults (R2 = 0.38; P   3 and void  3 and void <5 had an overall diagnostic ability for underhydration of 89% with sensitivity and specificity of 100% and 62%, respectively. CONCLUSIONS Urine color alone and the combination of urine color with void number can a valid and simple field-measure to detect underhydration based on elevated urine osmolality.
    • Correction