The Effect of Gamma Irradiation on Anterior Cruciate Ligament Allograft Biomechanical and Biochemical Properties in the Caprine Model at Time Zero and at 6 Months After Surgery

2006 
Background: High levels of gamma irradiation are required to eliminate the risk of bacterial and viral transmission during implantation of musculoskeletal allografts. The effects of high levels of gamma irradiation on anterior cruciate ligament allograft biomechanics are still not known.Hypothesis: High-dose gamma irradiation (4 Mrad) adversely affects anterior cruciate ligament allograft biomechanics at surgery and at 6 months after surgery and affects biochemistry at 6 months.Study Design: Controlled laboratory study.Methods: Bilateral anterior cruciate ligament reconstructions were performed in 18 adult goats, with one knee receiving an irradiated patellar tendon allograft (4 Mrad) and the other receiving a frozen control allograft (0 Mrad). In 6 recipients (time zero group), graft pairs were tested immediately after sacrifice, and load relaxation of the femur-allograft-tibia preparation was measured during cyclic anterior displacement. Twelve recipients received bilateral anterior cruciate ligament re...