Accident Analysis of Fukushima Daiichi Nuclear Power Plant Unit 2 by the SAMPSON Severe Accident Code

2014 
The transient process of the accident at the Fukushima Daiichi Nuclear Power Plant Unit 2 was analyzed by the severe accident analysis code, SAMPSON. One of the characteristic phenomena in Unit 2 is that the reactor core isolation cooling system (RCIC) worked for an unexpectedly long time (about 70 h) without batteries and consequently core damage was delayed when compared to Units 1 and 3. The mechanism of how the RCIC worked such a long time is thought to be due to balance between injected water from the RCIC pump and the supplied mixture of steam and water sent to the RCIC turbine. To confirm the RCIC working conditions and reproduce the measured plant properties, such as pressure and water level in the pressure vessel, we introduced a two-phase turbine driven pump model into SAMPSON. In the model, mass flow rate of water injected by the RCIC was calculated through turbine efficiency degradation the originated from the mixture of steam and water flowing to the RCIC turbine. To reproduce the drywell pressure, we assumed that the torus room was flooded by the tsunami and heat was removed from the suppression chamber to the sea water. Although uncertainties, mainly regarding behavior of debris, still remain because of unknown boundary conditions, such as alternative water injection by fire trucks, simulation results by SAMPSON agreed well with the measured values for several days after the scram.Copyright © 2014 by ASME