Performance of 500-mu-m thick silicon microstrip detectors after irradiation
2002
Abstract This paper investigates the performance of 500 μm thick silicon microstrip detectors before and after heavy irradiation. Prototype sensors, produced by STMicroelectronics, have been extensively studied using laboratory measurements, a radioactive source and a beam of minimum ionising particles. The comparison with a standard 300 μm sensor shows that the collected charge in thick devices scales linearly with thickness. By over-depleting the irradiated devices, the pre-irradiated charge collection efficiency is fully recovered. The measured noise is in good agreement with expectations. Although more work is needed, the paper shows that 500 μm thick devices are a promising technology for very large tracking systems.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
2
References
2
Citations
NaN
KQI