Long-Term Hemodynamic Performance of the Aortic Valve After David I: An Echocardiographic Study
2015
Despite optimal hemodynamics at rest, the performance of the aortic valve under stress conditions long after David I procedure is still debated. From 2001-2014, 73 patients underwent reimplantation with David I technique. Aortic valve function of 13 patients (age 61.2 ± 8.72) with a follow‐up of at least 5 years (6.3 ± 0.9 years) was assessed at exercise echocardiographic stress test on a stationary cycle. Patients who had undergone concomitant procedure, with recurrent aortic insufficiency or mitral valve incompetence, were excluded. In all, 8 healthy volunteers served as controls. Transvalvular gradients progressively increased during the steps in both groups ( P -within P -between 2 ; EOA index 2.0 ± 0.3cm 2 /m 2 ). In conclusion, David I procedure ensures good hemodynamics during high-flow conditions at long-term follow-up. The reimplantation of the functional aortic annulus inside a rigid tube determines a paradoxical reduction of functional aortic valve area, secondary to the increased stroke volume, without any clinically relevant increase in transvalvular gradients. These data confirm the reliability of David I in the long term, even under physical stress conditions.