Undulator Transportation Test Results

2010 
A test was performed to determine whether transporting and handling the undulators makes any changes to their properties. This note documents the test. No significant changes to the test undulator were observed. After the LCLS undulators are tuned and fiducialized in the Magnetic Measurement Facility (MMF), they must be transported to storage buildings and transported to the tunnel. It has been established that the undulators are sensitive to temperature. We wish to know whether the undulators are also sensitive to the vibrations and shocks of transportation. To study this issue, we performed a test in which an undulator was measured in the MMF, transported to the tunnel, brought back to the MMF, and re-measured. This note documents the test and the results.