Emittance and Phase Space Tomography for the Fermilab Linac

2013 
The Fermilab Linac delivers a variable intensity, 400-MeV beam to the The MuCool Test Area experimental hall via a beam line specifically designed to facilitate measurements of the Linac beam emittance and properties. A 10 m, dispersion-free and magnet-free straight utilizes an upstream quadrupole focusing triplet in combination with the necessary in-straight beam diagnostics to fully characterize the transverse beam properties. Since the Linac does not produce a strictly elliptical phase space, tomography must be performed on the profile data to retrieve the actual particle distribution in phase space. This is achieved by rotating the phase space distribution using different waist focusing conditions of the upstream triplet and performing a de-convolution of the profile data. Preliminary measurements using this diagnostic section are reported here.