Biomechanical Analysis of Stability of Posterior Antiglide Plating in Osteoporotic Pronation Abduction Ankle Fracture Model With Posterior Tibial Fragment

2017 
Background:We performed a biomechanical comparison of 2 methods for operative stabilization of pronation-abduction stage III ankle fractures; group 1: Anterior-posterior lag screws fixing the posterior tibial fragment and lateral fibula plating (LSLFP) versus group 2: locked plate fixation of the posterior tibial fragment and posterior antiglide plate fixation of the fibula (LPFP).Methods:Seven pairs of fresh-frozen osteoligamentous lower leg specimens (2 male, and 5 female donors) were used for the biomechanical testing. Bone mineral density (BMD) of each specimen was assessed by means of dual-energy x-ray absorptiometry. After open transection of the deltoid ligament, an osteotomy model of pronation abduction stage III ankle fracture was created. Specimens were systematically assigned to LSLFP (group 1, left ankles) or LPPFP (group 2, right ankles). After surgery, all specimens were evaluated via CT to verify reduction and fixation. Axial load was then applied onto each specimen using a servohydraulic t...
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    41
    References
    14
    Citations
    NaN
    KQI
    []