Analysis of the Mount Laguna Photovoltaic Cell Failure

1981 
From summary: The purpose of this analysis is to provide photovoltaic (P/V) system design and field engineers with an understanding of the primary factors which can cause individual P/V cells in a module or an array to be forced into reverse bias and eventual failure and to provide guidelines for the adequate protection of the cells.