Structural design of residential buildings according to Eurocode

2020 
In this paper, the dimensioning of the load-bearing structures A, B and C of building complex in the surroundings of Salzburg, Austria is given. The floors of object A are underground floor, ground floor and two floors, and for objects B and C it is underground floor, ground floor, first floor and the attic. These buildings have an underground shared garage. The foundation is 30 cm thick reinforced concrete slab, with capitals 200/200 cm, thickness dpp = 20 cm that are constructed in the middle part of the garage under the columns. Other underground parts of the buildings are the basements of each individual building. In addition to the common garage, the buildings have a common part of the ground floor, which connects the separate buildings. The construction of the garage at ground level is in the form of reinforced concrete slab with thickness dp = 35 cm with reinforcement-capitals under the columns with thickness dkpl. = 20 cm. The foundation and the ground floor slab are separated by an expansion joint in the axis 7. The waterproofing of the ground floor slab is achieved uniquely for the whole slab of the complex. Special attention is paid to the thermal calculation.