Analysis on Fracture Causes of Condensate Water Pump Shaft

2014 
Failure causes on a condensate pump shaft were discussed by means of macroscopic observation, chemical composition analysis, metallurgical microstructure inspection, mechanical property tests and stress analysis. The experimental results showed that the improper material with disqualified chemical composition, improper microstructure and poor mechanical properties acted as inherent factor. In addition, structure design that led to stress concentration contributed to the failure as external factor. Finally, fatigue fracture happened at the reduce section of the pump shaft.