Reliability of the portable gait rhythmogram in post-stroke patients.

2020 
BACKGROUND Gait analysis, such as portable gait rhythmogram (PGR), provides objective information that helps in the quantitative evaluation of human locomotion. OBJECTIVE The purpose of this study was to assess the reliability of PGR in post-stroke patients. METHODS Two raters (A and B) examined 48 post-stroke patients. To assess intra-rater reliability, rater A tested subjects on three separate occasions (Days 1, 2, and 3). To assess inter-rater reliability, raters A and B independently tested participants on the same occasion (Day 3). RESULTS There was no significant systematic bias between test occasions or raters. Intraclass correlation coefficient values were 0.93-0.97 for intra-rater reliability at both the comfortable speed and maximum speed, and 0.97-0.98 (comfortable speed) and 0.97-0.99 (maximum speed) for inter-rater reliability. The standard error was 1.25-1.49 (comfortable speed) and 1.62-1.77 (maximum speed) for intra-rater investigation, and 1.04-1.32 (comfortable speed) and 0.91-1.26 (maximum speed) for inter-rater investigation. At the 90% confidence level, the minimum detectable change ranged from 2.9-4.1%, and the error of an individual's score at a given time point ranged from ±2.1-2.9%. CONCLUSIONS Based on this excellent reliability of the PGR in post-stroke patients, it can be recommended as a simple test of gait analysis in this population.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    29
    References
    0
    Citations
    NaN
    KQI
    []